IXXAT CAN-CR300 4 channel CAN/CAN FD Repeater optional bus termination
CAN-CR300 repeater with four CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation.
IXXAT CAN-CR300 4 channel CAN/CAN FD Repeater optional bus termination
Product Images
IXXAT CAN-CR300 4 channel CAN/CAN FD Repeater optional bus termination: No Termination
$776.00
SKU: GC-IXT-CR300
MPN: 1.01.0210.40200
Manufacturer: Ixxat
Termination Option
-
$776.00
-
$776.00
We Have You Covered
Product Information
Product Description
The Ixxat CAN-CR300 repeater with 4 CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems, and offers galvanic isolation. The flexibility to optimize network structures frees them from CAN bus structure constraints by enabling extended layouts (stub lines, star and tree topologies).
The device can be purchased with or without integrated bus termination resistors. With the termination option (120 Ohm, switchable via DIP switch), the termination resistors prevent reflections on the line ends and ensure optimum communication.
It's designed for industrial environments by meeting high demands for robustness, temperature ranges, and safety. With its fast and transparent operation, there is minimal impact on real-time behavior equivalent to a short line length (ca. 35 m/175 ns delay). With transparent transmission, the repeater is compatible with all higher layer protocols.
Network Reliability
The CAN-CR300 ensures system reliability by electrically isolating CAN/CAN FD segments and power which auto-separates network faults and keeps the network operational. In case of disturbances in the CAN lines, the repeater automatically disconnects the affected segment and restores it after the fault is resolved, ensuring uninterrupted network operation. Network components can be galvanically isolated up to 1 kV. This reliably enhances the protection of the device against damage to electronics caused by voltage peaks.
Combined CAN and CAN FD interfaces in 1 device.
Equipped with 4 CAN/CAN FD channels, the CAN-CR300 can be used to establish a physical coupling and galvanic isolation of two segments of both CAN and CAN FD bus systems.
Application Sample
CAN repeaters can be used to better adapt the cable routing to ambient conditions. Stub lines can be made, and the bus structure can be expanded to a star/tree structure, which saves cable lengths. Shorter cable lengths reduce interference on the signal lines and enable higher bit rates. Segments connected via repeaters are galvanically decoupled, and therefore, offer overvoltage protection for connected participants.
Order Summary
SKU | Termination Resistors | Manufacturer Part # (MPN) |
GC-IXT-CR300 | No | 1.01.0210.40200 |
GC-IXT-CR300-T | Yes | 1.01.0210.40000 |
Features
- Robust industrial use for operation, temperature ranges and safety
- Fast and transparent operation
- Flexibility in CAN FD network design
- Cost savings due to simple wiring
- Enhanced network reliability
- Improved network monitoring and fault recovery
- Increased system protection
- CAN and CAN FD interfaces combined in 1 device
- Integrated bus termination resistors optional
Documents and Drivers
Documentation
CAN-CR300 Repeater User Manual
CE - Declaration of Conformity
CAN-CR300 Product Dimensions Diagram
Specifications
Content of Delivery
- CAN FD repeater
- User manual
Dimensions (W x H x D)
105 x 114 x 22.5 mm (4.1 x 4.5 x 0.9 in)
Weight
No termination resistors: 220 g (0.49 lbs)
With Termination resistors: 170 g (0.37 lbs)
Mounting
DIN rail mount (bracket included)
Current Consumption
- Type Value at Vcc Nom (mA): 90
- Max value at Vcc nom (mA) No Termination Resistors: 125
- Max value at Vcc nom (mA) With Termination Resistors: 100
Input Voltage (V)
+9 V to +36 V DC
Isolation
1 kV DC for 1 sec.
Termperature
- Operating: -20°C ~ 70°C (-4°F ~ 158°F)
- Storage: -40°C ~ 85°C (-40°F ~ 185°F)
- Relative Humidity: 10 to 95 %, non-condensing
Enclosure
IP20, Polyamide housing for top hat rail mounting
Certifications & Standards
- CE
- FCC
- WEEE Category: IT and telecommunications equipment
- ETIM Classification: EC000698
- Protection Class IP: IP20
Connectors / Input / Output
4 x screw terminals, 1 x power connector
CAN Features
- CAN Mode: CAN high-speed (ISO 11898-2) with CAN choke
- CAN Baud Rate: Up to 1 Mbit/s
CAN/CAN FD Features
- CAN FD Mode: ISO CAN FD, nonISO CAN FD
- CAN FD Baud Rate: Arbitration rate up to 1000 kBit/s, data rate up to 8000 kBit/s (verified by testing). User defined bit rates are possible.
- CAN FD Transceiver: MCP2562FD
Have a Special Request?
Please fill out the information below and our sales team will respond within 1 business day.
What you can expect from Grid Connect:
- High quality industrial networking and IoT solutions.
- Hundreds of product options to fit your needs, many available to ship same or next day.
- Unmatched technical support.
- Customization options to fit your needs.
- Price match guarantee on all products.
Please fill out the information below and our sales team will provide a quote within 1 business day.
Enter up to two product names/SKUs and up to three quantities for each product. If more products/quantity quotes are needed, please include your requests in the message section below.
Please provide information where you'd like the products shipped to so we can give you the most accurate quote possible.
Please help us understand your use case so we can provide you with the best possible solution. This step is optional, so please feel free to skip it if you'd like.
Please confirm your request and we will get back to you within 1 business day.
Thanks for submitting your quote request. You should receive an email with a copy of your request shortly, and a member from our sales team will reply to you within 1 business day.